| Bacharach PCA 3 Four Gas O2, CO, NO, NO2 Combustion Analyzer 24-8444 Busy technicians and boiler contractors who need to ensure safe operating conditions, determine combustion efficiency and perform emissions testing rely on Bacharach’s PCA®3. This lightweight handheld instrument is the industry’s first advanced portable combustion analyzer with a full color graphic display for superior visibility and user-friendly interface. Super bright backlighting, zoom display feature, dimming mode function and the most sensor configuration in its class provides the user with best-in-class instrumentation. PCA®3 is designed for on-demand or semi-continuous sampling of light industrial, institutional, commercial and residential furnaces, boilers and appliances. With sturdy metal gas and draft connectors and rugged construction plus simple operation and maintenance the PCA®3 is the new workhorse of the industry. Features and Benefits Analyzer Functionality- Directly measures and displays Flue Gas Oxygen (O2), Carbon Monoxide (CO), Stack Temperature, Draft, Differential Pressure, Combustion Air Temperature
- Optionally measures and displays Nitric Oxide (NO), Nitrogen Dioxide (NO2) and Sulfur Dioxide (SO2)
- Calculates and displays Combustion Efficiency (EFF), Excess Air (EA), Carbon Dioxide (CO2), NOx and Oxygen reference values
- Ten selectable fuels plus the ability to custom-load fuels
- Stores 1,000 tests (500 in memory and 500 in logged memory)
Smart Sensors- Instrument includes a pre-calibrated Oxygen (O2) sensor and a pre-calibrated B-Smart® Carbon Monoxide (CO) sensor
- Unique B-Smart® sensor technology saves downtime and calibration costs
- Best-in-Class sensor configuration flexibility allows purchased configurations or simple upgrade in the field
- Sensor options include pre-calibrated B-Smart® NO, NO2, SO2 and CO high sensors
Graphic Display- 320 x 240 pixel full color graphic display for superior visibility
- Super-bright backlighting and zoom capability to ensure effortless readability in any low light boiler and furnace room situations
- Easily change language parameters to display in formation in English, French or Spanish
- Dimming mode function helps extend battery life
Rugged Design and Construction- Sturdy metal gas and draft connectors for added durability in the field
- Tough ABS housing with rugged rubberized over-molding and protective boot with magnet
Specifications:| Measurement Ranges | North American Version |
|---|
| Primary/Ambient Air Temperature | -4° to 999°F | | Stack Temperature | -4° to 2192°F | | Oxygen | 0 to 20.9% | | Carbon Monoxide (H2 Compensated) | 0 to 4,000 ppm | | Carbon Monoxide, (High Range) | 4,001 to 20,000 ppm | | Nitric Oxide | 0 to 3,000 ppm | | Nitrogen Dioxide | 0 to 500 ppm | | Sulfur Dioxide | 0 to 5,000 ppm | | Pressure/Draft | -72 to +72 inwc | | Calculated Ranges | Combustion Efficiency | 0.1 to 100% |
|---|
| Excess Air | 1.0 to 250% | | Carbon Dioxide (Dry Basis) | 0 to Fuel Dependent Maximum | | NOx (NO + NO2) | 0 to 3,500 ppm | | NOx referenced to % O2 | 0 to 9,999 ppm | | CO referenced to % O2 | 0 to 9,999 ppm | | NO referenced to % O2 | 0 to 9,999 ppm | | NO2 referenced to % O2 | 0 to 9,999 ppm | | SO2 referenced to % O2 | 0 to 9,999 ppm | | Accuracy | Oxygen | ± 0.3% O2 (Flue Gas) |
|---|
| Stack or Flue Gas Temperature | ± 4°F between 32 and 255°F (± 2°C between 0 and 124°C) | ± 6°F between 256 and 480°F (± 3°C between 125 and 249°C) | ± 8°F between 481 and 752°F (± 4°C between 250 and 400°C) | | Primary-air/Ambient Temperature | ± 2°F between 32 and 212°F (± 1°C between 0 and 100°C) | | Pressure/Draft | ± 2% Reading or 0.02 inwc -1 to 10 inwc | | ± 3% of Reading between ± -40 and ± 40 inwc | | CO | ± 5% of Reading or ± 10 ppm in the range of 0-2000 ppm CO | | ± 10% of Reading between 2001 to 4,000 ppm | | NO | ± 5% of Reading or ± 5 ppm whichever is greater between 0 to 2000 ppm NO | | NO2 | ± 5% of Reading or ± 5 ppm whichever is greater between 0-500 ppm NO2 |
| Memory | 500 Complete Combustion Test Records |
|---|
| Logged Memory | 500 Complete Logged Combustion Test Records |
|---|
| Selectable Fuels | Natural Gas, Oil #2, Oil #4, Oil #6, Propane, Coal, Wood, Kerosene, Bagasse and Digester Gas |
|---|
| Size | 9"H x 3"W x 2.5" (22.9 cm x 7.6 cm x 6.3 cm) |
|---|
| Weight | 1.4 lbs (0.6 kg) |
|---|
| Power Source | Four Disposable AA Alkaline Batteries. Optional Universal AC Adapter (100 to 240 Volts at 47 to 63 Hz) |
|---|
| Display | Full Color Graphic Display (320 x 240 pixels) |
|---|
| Warm Up Time | 60 Second Total Warm Up Time (sensors are checked and autozeroed during warm up) |
| |
|