• ±0.05% accuracy • Automatic calibration • User selectable auto power-off • Includes test leads, soft carrying case and batteries
SPECIFICATIONS: output function Voltage Range: 10V Output Range: 0.00 to 11.000V Resolution: 1mV Accuracy: ±0.05% setting Current Range: 20mA Output Range: 0.000 to 22.000mA Resolution: 0.001mA Accuracy: ±0.05% setting + 4µA Analogue Transducer: -20mA Output Range: 0.000 to -22.000mA Resolution: 0.001mA Accuracy: ±0.05% setting + 4µA Loop Power: 24V Accuracy: ±10% Power Supply: Single 9V alkaline battery Battery Life: Approx. 20 hours Ambient Conditions: -10 to 55°C; ≤ 80% RH Dimensions: 200 x 100 x 40mm w/ holster Weight: 550g w/ holster
|